  Datasheet File OCR Text:
  patent pending streetsense tm series led street light for roadway and area illumination
www.dialight.com 2 streetsense ? led street light features and benefits patented optics exclusive precision optics and unique angled mechanical design for precise light that provides minimal light while providing un iform illumination ? uniform light distribution while delivering sharp cut-off, zero up-light ? reflectors are precision manufactured via injection molding and coated with a highly specular optical coating via vacuum-metalization ? precision engineered reflectors and leds are coupled to metal clad printed circuit board. light engine is sealed in an optically optimized premium glass lens ? dedicated ip66 optical cavities for led arrays maximizes the efficacy and control of distribution from each light engine module ? optical light engines are optimally aimed to maximize light collection and directional distribution onto the application area ? high brightness output leds deliver exceptional fixture efficacy (up to 92 lm/w) in a choice of three superior quality color temperatures; cool (5000k 300), neutral (4300k 300), warm (3300k 300) with a minimum cri of 70 ? scotopic to photopic (s/p ratio) of led is 1:1.6 for 4000k ? lens also available in uv and abrasion resistant polycarbonate clear and frosted lens ? no uv or ir emissions ? optional house-side shield is available to further reduce back-side light trespass in residential areas ? anti-reflective coating on the house-side shield prevents the introduction of unwanted glair to the roadway
? high grade aluminum alloy a360 construction for superior strength and durability ? in contrast with horizontal or planer heat sinking systems, the deep troughs between heat sink fins are wide and angled to achieve a self-cleaning design and prevent debris build-up ? exclusive physical design gives rise to an exceptional passive thermal management system ? vent openings in light engine casting paired with fins are optimized for increased air flow velocity and thermal plume assureing a minimum operating temperature of the leds and driver www.dialight.com streetsense ? led street light features and benefits innovative design designed for new construction and easily retrofits with existing hid fixtures. ? metal clad pcbs used in light engine are secured directly to the cast aluminum housing for superior thermal transfer and low in-situ temperature (board level temperature) ? thermal overload protection circuitry prevent internal temperatures from reaching high levels thereby increasing long term reliability and allowing operation up to 74c ? rugged cast aluminum housing is subjected to a multistage (cleaning and sealing) per process aama 2604 and top coated with a super durable, polyester powder coated finish that is available in 5 standard colors ? finish is resistant to blistering, excessive fading or corrosion during warranty period ? terminal block sized to allow for wire gauges from #14 awg to #6 awg and is accessible from under side of fixture ? salt spray tested for corrosion - 3,000 hours per astm b117-97 ? withstands shock & vibration to caltrans 611 levels C 3.0g peak-to-peak, 2 million cycles ? stainless steel, sae, captive hardware ? large, easy to read two axis bubble level allow installer to quickly and efficiently level fixture during installation ? rugged heavy gauge, 4 bolt, aluminum clamp with stainless steel hardware secures fixture to pole arm ? adjustable pole mount connection can accommodate a 2 ip (2.375 od) pipe with provision for adjustment of 5 at 2.5 increments ? unique hinged polycarbonate bottom cover provides tool-less access to terminal blocks and pole arm via a single trigger-latch for quick and easy luminaire mounting 3
www.dialight.com streetsense ? led street light features and benefits electrical ruggedized driver design and thermal management system ensure maximum energy efficiency and reliability ? dialights custom led drivers are constant current sources well suited for the load and the particular lighting application ? field replaceable, primary fused, output isolated drivers are fully potted and encased in an aluminum extrusion for emi noise immunity and thermal protection ? offering high efficiency and power factor with ultra low thd, the led drivers incorporate overload and no load protection circuitry ? universal inputs 100-277v ac, 50/60hz and 347-480v ac, 50/60hz ? led driver mtbf per telcordia sr-332 C 5,10,040 hrs at 13.8c (average yearly temperature of five major cities) ? safety grommets in casting through-holes prevent abrasions to electrical wire insulation ? robust, integrated 6kv/6kva or 10kv/10kva surge protection circuitry incorporate movs designed to actively clamp line voltages to safe levels per ansi/ieee c62.41.2-2002 cat c ? ip65 rated led drivers ? 7 year full performance warranty with option for 10 years ? factory burn-in (24 hr to avoid infant fatality) lifetime l70 / tm-21 lifetime report at 500ma C calculated lifetime = 914,000 hrs; reported lifetime = 60,500 hrs 4
mechanical information fixture weight: 16lbs (42w, 63w, 82w) 25lbs (126w, 164w) 34lbs (189w, 246w) epa (sq. ft): 0.60 (42w, 63w, 82w) 0.87 (126w, 164w) 1.13 (189w, 246w) mounting: accommodates 1.25 (1.66 od) - 2 (2.375 od) 31.75mm (42.16mm od) - 50.8mm (60.32mm od) pipe. provision for adjustment of +/- 5 at 2.5 increments electrical specifications operating voltage: universal inputs 100-277vac, 50/60hz 347-480vac 50/60hz total system power consumption: see ordering info on pg. 6 operating temp: -40f to 165f (-40c to 74c) ambient terminal block: #14 awg (1.6mm) to #6 awg (4.1mm) wire and accessible via hinged tool less entry noise requirements / emc: fcc title 47, subpart b, section 15, class a device. rf immunity; 10v/m, 80mhz-1ghz transient protection 100-277vac, 50/60hz: open circuit surge protection 6kv standard per ansi/ieee c62.41. 2.2002 cat c low or open circuit surge protection 10kv standard per ansi/ieee c62.41. 2.2002 cat c high 347-480vac 50/60hz: open circuit surge protection 10kv standard per ansi/ieee c62.41. 2.2002 cat c high thd: <15% (100 - 240vac) <20% (277vac) <20% (347-480vac) power factor: >0.90 material housing: die cast aluminum alloy a360 polymeric materials ul94 v0 flame retardant materials finish: polyester powder coat for superior corrosion resistance gray - ral 7040 bronze - ral 7022 green - ral 6020 black - ral 9005 white - ral 9010 lens: abrasion and uv resistant polycarbonate optically optimized, tempered glass photo controller socket: standard nema three prong twist lock, socket with shorting cap, as per ansi c136.10 photometric information cri: >70 cct: 5,000k (cool white) 4,300k (neutral white) 3,300k (warm white) optics: ies type ii, iii, iv, v all values typical unless otherwise stated all lumen values are typical (tolerance +/- 10%) www.dialight.com streetsense? series led street light 34.7 (880) 26.5 (674) 18.4 (467) 4.8 (122) 14.7 (372) dimensions in inches (mm) certifications and ratings: ? ul 1598 (suitable for wet locations) ? ul 8750 ? ul 1012 ? ul 1449 ? ce ? csa c22.2 no. 250.0-08 ? ip66 compliances: ? rp-8-00 (r2005) ? iec 60529 (ip 66) ? ansi 1012 ? ansi c 136.15-2011 ? ansi/ieee c62.41.2-2002 ? ansi/nema/anslg c78.377-2008 ? ansi c136.2-2004 (r2009) ? ansi c136.3-2005 ? ansi c136.10-2006 ? ansi c136.21-2004 ? ansi c136.25-2009/iec 60529 ? ansi c136.31-2001 ? ansi c136.32-2006 ? ansi c136.37-2011 ? astm b117-97 ? astm b117 - salt spray (3000 hours) ? conforms with caltrans vibration test 611 C 3g vibration (2,000,000 cycles) ? meets arra requirements (must be specified when ordering) ? ida dark sky ? rohs test reports: ? lm-79 ? lm-80 ? rp-8-00 ? tm21 accessories (ordered separately): ? photo controller - part number - sl-pc01r ? house side shield - part number - sl-shield-kit ? lumitrol? streetlight control module (consult factory) ? ansi label (consult factory) 5 189w, 246w 126w, 164w 42w, 63w, 82w
www.dialight.com streetsense? series led street light ordering information part number initial fixture lumens 1 total system power consumption lumen per watt color bug rating epa (sq. ft) number of light engines sl3c4blgh 3,800 42 90 cool white b1u1g1 0.60 1 sl3c4clgh 5,700 63 90 cool white b1u2g1 0.60 1 sl3c4dlgh 6,900 82 84 cool white b2u3g2 0.60 1 sl3c4hlgh 11,500 126 91 cool white b2u3g2 0.87 2 sl3c4ilgh 13,750 164 84 cool white b3u3g3 0.87 2 sl3c4rlgh 17,000 189 90 cool white b3u3g3 1.13 3 sl3c4slgh 20,750 246 84 cool white b3u3g3 1.13 3 sl3n4blgh 3,800 42 90 neutral white b1u1g1 0.60 1 sl3n4clgh 5,700 63 90 neutral white b1u2g1 0.60 1 sl3n4dlgh 6,900 82 84 neutral white b2u3g2 0.60 1 sl3n4hlgh 11,500 126 91 neutral white b2u3g2 0.87 2 SL3N4ILGH 13,750 164 84 neutral white b3u3g3 0.87 2 sl3n4rlgh 17,000 189 90 neutral white b3u3g3 1.13 3 sl3n4slgh 20,750 246 84 neutral white b3u3g3 1.13 3 sl3w4blgh 3,100 42 74 warm white b1u1g1 0.60 1 sl3w4clgh 4,700 63 75 warm white b1u2g1 0.60 1 sl3w4dlgh 5,700 82 70 warm white b2u2g2 0.60 1 sl3w4hlgh 9,250 126 73 warm white b2u3g2 0.87 2 sl3w4ilgh 11,500 164 70 warm white b3u3g3 0.87 2 sl3w4rlgh 14,000 189 74 warm white b3u3g3 1.13 3 sl3w4slgh 17,000 246 69 warm white b3u3g3 1.13 3 sl-3 c 4 c l g g 2 - ii 3 - iii 4 - iv 5 - v c - 5,000k n - 4,300k w - 3,300k 4 - 120-277v ac 6kv surge pro- tection 5 - 120-277v ac 10kv surge protection 7 - 347-480v ac 10kv surge protection b - 42w c - 63w d - 82w h - 126w i - 164w r - 189w s - 246w n - no photo controller receptacle r - photo controller receptacle only l - shorting cap i - lumitrol? streetlight control module g - gray b - bronze r - green k - black w - white g - glass h - polycarbonate ies type cct 1 voltage wattage controller housing color lens 6 blank - ul eu - ce certification 1 polycarbonate lens option will decrease lumen values by 8%
40 watt iso-illuminance chart fc - lux intensity distribution curve (cd) mounting height - 25 (7.6m) www.dialight.com measurement data - ies type iii mounting height multiplier 10 (3.0m) 6.25 15 (4.6m) 2.778 20 (6.1m) 1.563 25 (7.6m) 1 30 (9.1m) 0.694 35 (10.7m) 0.51 40 (12.7m) 0.391 45 (13.4m) 0.309 50 (15.2m) 0.25 7 60 watt iso-illuminance chart intensity distribution curve (cd) mounting height multiplier 10 (3.0m) 6.25 15 (4.6m) 2.778 20 (6.1m) 1.563 25 (7.6m) 1 30 (9.1m) 0.694 35 (10.7m) 0.51 40 (12.7m) 0.391 45 (13.4m) 0.309 50 (15.2m) 0.25 80 watt iso-illuminance chart intensity distribution curve (cd) mounting height multiplier 10 (3.0m) 6.25 15 (4.6m) 2.778 20 (6.1m) 1.563 25 (7.6m) 1 30 (9.1m) 0.694 35 (10.7m) 0.51 40 (12.7m) 0.391 45 (13.4m) 0.309 50 (15.2m) 0.25 - location of streetlight spacing of each box is equal to mounting height in feet (meters). ex: 40 (12.2m) mounting height = each box is 40 (12.2m), 30 (9.1m) mounting height = each box is 30 (9.1m) values shown are for cool white and neutral white units, for warm white multiply the fc or lux value by .82 mounting height - 25 (7.6m) mounting height - 25 (7.6m) 120 watt iso-illuminance chart intensity distribution curve (cd) mounting height foot candle multiplier 10 (3.0m) 9 15 (4.6m) 4 20 (6.1m) 2.25 25 (7.6m) 1.44 30 (9.1m) 1 35 (10.7m) 0.735 40 (12.7m) 0.563 45 (13.4m) 0.444 50 (15.2m) 0.36 mounting height - 30 (9.1m)
www.dialight.com 8 measurement data - ies type iii 180 watt iso-illuminance chart intensity distribution curve (cd) mounting height - 35 (9.1m) mounting height multiplier 10 (3.0m) 9 15 (4.6m) 4 20 (6.1m) 2.25 25 (7.6m) 1.44 30 (9.1m) 1 35 (10.7m) 0.735 40 (12.7m) 0.563 45 (13.4m) 0.444 50 (15.2m) 0.250 240 watt iso-illuminance chart intensity distribution curve (cd) mounting height - 40 (12.1m) mounting height multiplier 10 (3.0m) 12.250 15 (4.6m) 5.444 20 (6.1m) 3.063 25 (7.6m) 1.960 30 (9.1m) 1.361 35 (10.7m) 1.000 40 (12.7m) 0.766 45 (13.4m) 0.309 50 (15.2m) 0.605 mdtfsl3x001_e dialight reserves the right to make changes at any time in order to supply the best product possible. the most current version of this document will always be available at: www.dialight.com/assets/brochures_and_catalogs/illumination/mdtfsl3x001.pdf warranty statement: except for the warranty expressly provided for [herein/above/below], dialight disclaims any and all other w arranties, express or mplied, including, without limitation, any warranties of merchantability, fitness for a particular purpose, title, and noninfri ngement. - location of streetlight spacing of each box is equal to mounting height in feet (meters). ex: 40 (12.2m) mounting height = each box is 40 (12.2m), 30 (9.1m) mounting height = each box is 30 (9.1m) values shown are for cool white and neutral white units, for warm white multiply the fc or lux value by .82 160 watt iso-illuminance chart fc - lux intensity distribution curve (cd) mounting height - 30 (9.1m) mounting height multiplier 10 (3.0m) 9 15 (4.6m) 4 20 (6.1m) 2.25 25 (7.6m) 1.44 30 (9.1m) 1 35 (10.7m) 0.735 40 (12.7m) 0.563 45 (13.4m) 0.444 50 (15.2m) 0.250


▲Up To Search▲   

 
Price & Availability of SL3N4ILGH

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X